Generator load worksheet fields

Generator running-load and starting-kVA record fields for Australian backup-power worksheets.

  • Power quality and backup · Worksheet fields
  • High-sensitivity table
  • Last checked 13 July 2026

Generator load fields for backup sizing

Show generator load record fields without selecting a generator set, transfer arrangement or final backup-power design.

Generator load fields
FieldPurposeTypical sourceBoundary
Running loadRecords steady load included in generator sizing.Load schedule or equipment dataConnected load and required backup load may differ.
Starting loadCaptures motor or equipment starting contribution.Motor calculator, product data or starter settingStarting method can change the apparent power materially.
Largest step loadShows the load change the generator must tolerate.Sequence or controls noteStep loading needs generator product review.
Voltage and phaseKeeps supply arrangement tied to the kVA record.Project or generator dataSingle-phase and three-phase values must not be mixed.
Transfer or backup scopeShows which loads are included during backup operation.Switchboard or transfer design recordThis table does not select transfer equipment.
  • Use this table to make generator sizing inputs traceable.
  • Generator selection needs manufacturer data, transfer design, fuel/runtime and competent review.

Before generator records feed sizing review

Capture running load, starting behaviour and duty assumptions before reviewing generator kVA or backup capacity.

Limits of generator load records
ItemValue
PurposeShow generator load record fields without selecting a generator set, transfer arrangement or final backup-power design.
How to use the sourceField table only; running-load and starting-kVA arithmetic lives on the generator calculator.
Standards and project contextAS/NZS 3010, AS/NZS 3000 and manufacturer context noted for project review; verify current sources and product data.
Where judgement is still neededUse this table for lookup, labelling or worksheet context; do not treat it as a project-specific calculation result.
Before relying on itConfirm current standards, local authority requirements, DNSP conditions, project documents and manufacturer data before relying on a decision.

Project record basis for generator load fields

Keep the project or equipment record, checked date and Australian site scope visible beside each load field.

Generator load fields source basis
ItemValue
SourceAUWiring generator load and starting-kVA calculator field model and Australian backup-power record practice.
Source typeProject or product record model
Derivation basisAUWiring field table for generator worksheets; generator-set ratings, transfer design and manufacturer requirements are not reproduced.
Last checked2026-07-13
Review intervalAnnual or when generator calculator fields, backup-power practice, standards context or manufacturer guidance changes.
Review triggerCalculator field change, standards update, generator product change, transfer arrangement change or project feedback.
Version usedR39-2026-07-13
Australian applicationAustralia; generator product data, transfer equipment, fuel/runtime requirements and project review govern final decisions.