PV array power calculator
Estimate PV array kW from entered module rating, modules per string, parallel strings and derate factor for Australian solar planning records.
Array kW = module W x modules per string x parallel strings / 1000; Derated array kW = Array kW x derate factor; DC/AC ratio = derated array kW / inverter AC kW- Modules per string and parallel strings are entered whole-number counts.
- Derate factor is entered by the user.
- DC/AC ratio is a handoff value, not an inverter approval.
- String voltage and string current remain separate checks.
| Variable | Meaning | Unit | Use |
|---|---|---|---|
| Wmodule | Module rating | W | Entered module power rating. |
| Ns | Modules per string | count | Entered number of modules in each series string. |
| Np | Parallel strings | count | Entered number of parallel strings. |
| Ntotal | Total modules | count | Modules per string multiplied by parallel strings. |
| Parray | Raw array power | kW | Module rating multiplied by total modules and divided by 1000. |
| Fderate | Derate factor | factor | Entered project derate applied to raw array kW. |
| Pderated | Derated array power | kW | Raw array power multiplied by derate factor. |
| Pinv | Inverter AC capacity | kW | Entered inverter AC capacity used for ratio comparison. |
| Ratio | DC/AC ratio | ratio | Derated array kW divided by inverter AC kW. |
More
PV array power calculator technical guide
Estimate PV array kW from entered module rating, modules per string, parallel strings and derate factor for Australian solar planning records.
Use this page when a PV design record needs a clear array power value from entered module rating and string counts. It gives raw array kW, derated array kW, total module count and a DC/AC ratio handoff. It does not approve the module layout or inverter selection.
PV Array Power Boundary
This calculator does not approve module layout, inverter suitability, string voltage, string current, isolator selection, export settings or installation compliance. It records arithmetic from values entered by the user.
| Task | Use this page? | Why |
|---|---|---|
| Total module count | Yes | The page multiplies modules per string by parallel strings. |
| Raw and derated array kW | Yes | The page owns module W and derate arithmetic. |
| String voltage | No | Use the PV string voltage calculator. |
| String current | No | Use the PV string current calculator. |
| Inverter approval | No | Product listings, DNSP requirements and manufacturer data remain external. |
Input Checklist
| Value | Where it normally comes from | Stop if |
|---|---|---|
| Module rating | Datasheet, module schedule or product record | The module W basis is unclear. |
| Modules per string | String layout record | It has not been checked against string voltage. |
| Parallel strings | Array layout record | It does not match the current or inverter record. |
| Derate factor | Project assumption, modelling note or reviewer input | It is copied without source. |
| Inverter AC capacity | Inverter schedule or product record | The capacity basis is not the same as the sizing worksheet. |
Review Workflow
- Name the PV array, string group or inverter input record.
- Enter module W from the product or schedule record.
- Enter modules per string and parallel strings from the layout record.
- Enter derate factor as 1 for raw array power or a lower source value when required.
- Enter inverter AC capacity if the DC/AC ratio handoff is useful.
- Read total modules, raw array kW and derated array kW before using the ratio.
- If the ratio is high, review inverter product data, export settings and project assumptions.
- Carry array kW into inverter sizing only as an entered planning value.
Worked Records
| Situation | Inputs | Result | Record use |
|---|---|---|---|
| Thirty-module array | 440 W modules, 10 per string, 3 strings, 0.95 derate | 13.2 kW raw, 12.54 kW derated | Handoff to inverter sizing. |
| High ratio review | 550 W modules, 12 per string, 4 strings, 15 kW inverter | 26.4 kW raw, 1.76 DC/AC ratio | Review product and export assumptions. |
| Small array handoff | 415 W modules, 8 per string, 2 strings, 0.9 derate | Small planning record | Keep array kW visible for downstream worksheets. |
Australian Context
PV array power records in Australia sit beside AS/NZS 5033 string and array context, AS/NZS 4777 inverter context, DNSP export conditions, product listings and manufacturer instructions. This page keeps the quantity arithmetic visible while leaving those external requirements outside the calculator.
Stop Points
- Module rating or derate factor has no source record.
- String count has not been checked with PV string voltage.
- Parallel string count does not match current or inverter records.
- DC/AC ratio is being treated as inverter approval.
- The result is being used as installation compliance approval.
Thirty-module array record
A 10S3P array uses 440 W modules and a 0.95 derate factor before inverter ratio review.
- Reference
- PV-ARRAY-1
- Module rating
- 440 W
- Modules per string
- 10
- Parallel strings
- 3
- Derate factor
- 0.95
- Total modules30
- Raw array power13.2 kW
- Derated array power12.54 kW
DC/AC ratio is 1.254 on the entered inverter capacity.
The derated array kW is ready to carry into inverter sizing, subject to product and string checks.
- Module rating is entered from product data.
- Derate factor is entered by the user.
- String voltage and product suitability are separate checks.
High ratio review
A larger array is compared with a 15 kW inverter to show when DC/AC ratio review is expected.
- Reference
- PV-ARRAY-REVIEW
- Module rating
- 550 W
- Modules per string
- 12
- Parallel strings
- 4
- Derate factor
- 1
- Total modules48
- Raw array power26.4 kW
- Derated array power26.4 kW
DC/AC ratio is 1.76 on the entered inverter capacity.
The DC/AC ratio is high, so inverter product data, export settings and project assumptions need review.
- The high module count is intentional.
- The derate factor is 1 for the comparison case.
- No inverter approval is made.
Small array handoff
A smaller 8S2P array is recorded before its kW value is used in downstream worksheets.
- Reference
- PV-ARRAY-SMALL
- Module rating
- 415 W
- Modules per string
- 8
- Parallel strings
- 2
- Derate factor
- 0.9
- Total modules16
- Raw array power6.64 kW
- Derated array power5.98 kW
DC/AC ratio is 0.996 on the entered inverter capacity.
The array power is a clear planning value, while string voltage and current remain separate tasks.
- Modules per string is entered as a whole number.
- Parallel strings are entered by the user.
- Australian product and installation context remains external.